MOXA EDS-4008-2MSC-HV Managed Ethernet Switch Price in Middle East-Qatar | Rockford Communication Solutions

Menu
Your Cart

Managed Switch With Multi-Mode SC Fiber Uplinks

The MOXA EDS-4008-2MSC-HV Managed Ethernet Switch combines six Fast Ethernet copper ports with two multi-mode SC fiber ports for uplinks. It adds ring redundancy and network management to an industrial network and runs from a high-voltage AC or DC supply. Rockford Communication Solutions supplies this model to customers in Qatar.

Copper Ports Plus SC Fiber on a High-Voltage Input

This switch is a managed switch for industrial networks. It lets devices on copper cabling share a backbone that uses fiber links. Power comes from a single high-voltage AC or DC input. The metal housing has a compact design for confined spaces and DIN-rail cabinets. In Industrial Network Infrastructure, it acts as the point where device-level copper links meet the fiber backbone.

Turbo Ring Redundancy, MXstudio and Port Security

  • Turbo Ring and Turbo Chain: MOXA ring and chain redundancy restores traffic after a link failure. RSTP, STP, MRP, ring coupling and dual-homing give further options.
  • MXstudio management: MXstudio gives a visual view of the network, while SNMP, RMON and LLDP support monitoring and diagnostics.
  • Port and access security: Broadcast storm protection, rate limiting, access control lists, static port lock, MAC sticky, SSH, RADIUS, TACACS+ and DHCP snooping limit misuse and overload.
  • Industrial protocols: EtherNet/IP, Modbus TCP and PROFINET IO Device support let automation systems work with the switch.
  • Traffic control: QoS, VLANs and IGMP snooping keep priority traffic moving and limit unnecessary multicast traffic.
  • Hardware-based time sync: PTP with power profiles gives precise time synchronization across devices.

EDS-4008-2MSC-HV Specifications

SpecificationValue
Ethernet ports6 x 10/100BaseT(X) (RJ45)
Fiber ports2 x 100BaseFX (multi-mode SC connector)
Input voltage110/220 VDC/VAC, single input (operating voltage 88 to 300 VDC, 85 to 264 VAC)
Power consumption11.09 W (max.)
Operating temperature-10 to 60°C (14 to 140°F)
Housing and IP ratingMetal housing, IP40
Dimensions55 x 140 x 120 mm (2.2 x 5.51 x 4.72 in)
Weight886 g (1.95 lb)
MTBF492,582 hrs (Telcordia Standard SR-332)

Uses in Video Monitoring, ITS and DCS Networks

MOXA names video and process monitoring, ITS, and DCS systems as uses of this range. Uses of this switch type include:

  • IP Surveillance and process monitoring: Fiber uplinks carry traffic from Fast Ethernet devices toward a scalable backbone.
  • Transportation Rail/Road: Intelligent transportation systems (ITS) are a named use of the series, and the rail and traffic control listings are noted below.
  • Automation: DCS systems benefit from ring redundancy and from EtherNet/IP, Modbus TCP, and PROFINET IO Device support.
  • Power/Utility: Substation networks can use the hardware-based time synchronization and the substation listings noted below.

DIN-Rail Mounting, Terminal Blocks and DIP Switches

  • Mount the switch on a DIN rail, or on a wall with the optional kit.
  • Wire power through two removable 4-contact terminal blocks.
  • The PWR-105-HV-I power module is pre-installed. If you replace the module, follow the specifications of the model that matches the new module.
  • Use the relay alarm output (1 A @ 24 VDC) and the one digital input for alarm signaling and external signals.
  • Set Turbo Ring, Master, Coupler and Reserve with the DIP switches.
  • Use the RS-232 console port (8-pin RJ45) and the reset button for local access. The LEDs show power, state, fault, ring and time sync status.

IEC 62443-4-2, Rail, Traffic Control and Substation Listings

The switch is listed for IEC 62443-4-2 Security Level 2, which supports secure industrial network design. Rail, traffic control and power substation environments are covered by EN 50121-4, NEMA TS2, IEC 61850-3 and IEEE 1613 Class 1. Safety and emissions listings include UL 61010-2-201, EN 62368-1 (LVD) and FCC Part 15B Class A.

Series Family and Storage Kits for the HV Model

  • Product family: This switch belongs to the Moxa EDS-4008 Series, which also includes copper-only, Gigabit uplink and PoE models. Choose this model when you need multi-mode SC fiber uplinks with a high-voltage AC or DC input.
  • Storage kits: The ABC-02-USB (0 to 60°C) and ABC-03-microSD-T (-40 to 85°C) tools back up and restore configuration, support firmware upgrades and store log files. Both are accessories sold separately.

Questions About the EDS-4008-2MSC-HV

Does the EDS-4008-2MSC-HV support PoE?

No. PoE ports are listed only on the EDS-4008-4P-2GT-2GS models in the series. This model has standard copper ports and fiber ports and does not supply power to connected devices.

Can the EDS-4008-2MSC-HV run on both AC and DC power?

Yes. The HV power module accepts AC or DC on the same single input, so one switch fits sites with either supply.

Can the EDS-4008-2MSC-HV use SFP modules in its fiber ports?

No. The two fiber ports are fixed multi-mode SC ports. SFP slots are listed only on the EDS-4008-2GT-2GS and EDS-4008-4P-2GT-2GS models, so choose one of those if the uplink needs interchangeable modules.

How does the EDS-4008-2MSC-HV differ from the EDS-4008-2MSC-HV-T?

The two share the same ports and HV power input. The difference is the operating temperature. The -T model works from -40 to 75°C, while the standard model works from -10 to 60°C.

How does the EDS-4008-2MSC-HV differ from the EDS-4008-2MSC-LV?

The two share the same port layout. The difference is the power module. The HV model takes a single high-voltage AC or DC input, while the LV model takes low-voltage DC with redundant dual inputs. Hazardous location and maritime approvals are listed for the LV models only.

How does the EDS-4008-2MSC-HV differ from the EDS-4008-2MST-HV?

The two share six copper ports and the HV power input. The difference is the fiber connector. The 2MSC model uses multi-mode SC connectors, while the 2MST model uses multi-mode ST connectors. Choose the one that matches your fiber cabling.

Send an inquiry with the Enquire Now button or contact Rockford with questions about the MOXA EDS-4008-2MSC-HV Managed Ethernet Switch in Qatar. Rockford offers pre-sales support, network design, consulting, technical support and training. Tell us your port, power and temperature needs and we will help you choose a model.