Single-Mode Fiber Switching for Industrial Backbones
The MOXA EDS-4008-2SSC-LV Managed Ethernet Switch is a managed Fast Ethernet switch with copper ports and single-mode fiber ports for industrial networks. It adds redundancy, security, and monitoring functions to the network backbone and accepts redundant dual power inputs. Rockford Communication Solutions supplies it to customers in Qatar.
Copper and Single-Mode Fiber in One Managed Switch
This managed Layer 2 switch joins copper-connected devices to a fiber backbone. Its copper ports serve local equipment. Its single-mode fiber ports carry traffic over longer runs to another cabinet or building. Two power inputs let you wire a backup supply. In industrial network infrastructure, the switch can form ring or chain links between cabinets. It also suits Automation Systems that need a scalable backbone for video monitoring, process monitoring, and DCS traffic.
Turbo Ring, Access Control and PROFINET on the EDS-4008-2SSC-LV
- Ring and chain redundancy: Turbo Ring, Turbo Chain, ring coupling, dual-homing, RSTP/STP, MSTP and MRP give the network several ways to recover when a cable or link fails.
- Access and traffic protection: Broadcast storm protection, rate limiting, access control lists, static port lock, MAC sticky, and DHCP snooping limit unwanted traffic and unknown devices.
- Secure management: SSH, HTTPS/SSL, RADIUS, TACACS+, and a login and password policy control who can configure the switch.
- EtherNet/IP, Modbus TCP and PROFINET IO Device: Automation systems can read the switch with industrial protocols they already use.
- QoS, VLANs and multicast control: Class of service, VLAN tagging, IGMP snooping and an IGMP querier help keep video and control traffic organised on a shared backbone.
- Monitoring and time sync: SNMP, RMON, LLDP, port mirroring, syslog and fiber check help locate faults. Hardware-based PTP with power profiles keeps device clocks aligned.
EDS-4008-2SSC-LV Specifications
| Specification | Value |
|---|---|
| Copper Ethernet ports | 6 x 10/100BaseT(X), RJ45 connector (auto-negotiation speed, full/half duplex mode, auto MDI/MDI-X connection) |
| Fiber ports | 2 x 100BaseFX, single-mode, SC connector |
| Typical single-mode distance | 40 km (G.652 fiber) |
| Input voltage | 12/24/48 VDC, redundant dual inputs (operating voltage 9.6 to 60 VDC) |
| Input current | 12-48 VDC, 1.50-0.40 A or 24 VDC, 0.70 A |
| Power consumption (max.) | 8.98 W |
| Operating temperature | -10 to 60°C (14 to 140°F) |
| IP rating and housing | IP40, metal |
| Dimensions | 55 x 140 x 120 mm |
| Weight | 882 g (1.94 lb) |
Rail, Marine, Substation and Process Monitoring Uses
The EDS-4008 Series is aimed at video and process monitoring, ITS, and DCS systems. These uses follow from the stated features of this product type.
- Transportation Rail/Road: ITS backbones can use ring redundancy and fiber links to connect roadside or station cabinets.
- Power/Utility: Substation networks can use hardware-based time synchronization with power profiles.
- Marine: Marine networks need equipment with marine approvals and cybersecurity certification.
- Automation: Process monitoring and DCS networks can read switch status through EtherNet/IP, Modbus TCP or PROFINET IO Device.
- IP Surveillance: Video monitoring traffic can be carried over fiber links and prioritised with QoS.
DIN-Rail Mounting With Redundant Power Wiring
- Mount the switch on a DIN rail, or on a wall with the optional kit.
- Wire power to the two removable 4-contact terminal blocks. The pre-installed power module is PWR-100–LV.
- Connect external equipment to the relay alarm output (1 A @ 24 VDC) and the digital input.
- Set ring roles with the DIP switches for Turbo Ring, Master, Coupler, and Reserve. A reset button is also fitted.
- Use the RS-232 console port (8-pin RJ45) for local configuration. HTTP, HTTPS and Telnet management are also supported.
- LED indicators are PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL and SYNC.
Marine, Substation and Hazardous Location Approvals
The switch is IEC 62443-4-2 Security Level 2 certified and carries IEC 61162-460 (switch role). This helps with secure industrial network design and marine cybersecurity requirements. Environmental approvals include DNV, ABS, NK, and LR for marine, EN 50121-4 for railway, NEMA TS2 for traffic control, and IEC 61850-3 with IEEE 1613 Class 1 for power substations. This model also lists ATEX, IECEx, and Class I Division 2 for hazardous locations, plus UL 61010-2-201 for safety.
How the EDS-4008-2SSC-LV Fits in the EDS-4008 Series
Product family: This model belongs to the MOXA EDS-4008 Series. Other models in the series offer multi-mode fiber, Gigabit copper and SFP uplinks, PoE ports, high-voltage power and wide-temperature versions. Choose the 2SSC-LV when single-mode fiber and low-voltage DC power fit the site.
Related products: Storage kits such as ABC-02-USB and ABC-03-microSD-T back up configuration, support firmware upgrades, and store logs. The accessory list also includes DIN-rail power supplies such as HDR-60-24 and NDR-120-48, and an MXview One node license for network management.
EDS-4008-2SSC-LV Questions on Fiber, Power and PoE
Can the EDS-4008-2SSC-LV run over long single-mode fiber links?
Yes. The two single-mode SC ports are made for long fiber runs. The reachable distance depends on the link budget of the fiber link. MOXA recommends an attenuator with a single-mode fiber transceiver to prevent damage from excessive optical power. The link budget must be larger than the dispersion penalty plus the total link loss.
How does the EDS-4008-2SSC-LV differ from the EDS-4008-2MSC-LV?
The EDS-4008-2SSC-LV uses single-mode SC fiber ports. The EDS-4008-2MSC-LV uses multi-mode SC fiber ports and has the same number of copper ports. Choose between them based on the type of fiber cabling at your site.
What changes in the EDS-4008-2SSC-LV power specifications if the power module is replaced?
The EDS-4008 Series uses modular power supplies, and the model name and power parameters follow the installed module. If the module is replaced, use the specifications of the model that matches the new module. For example, a PWR-105-HV-I module corresponds to the HV model specifications.
Does the EDS-4008-2SSC-LV supply PoE?
No. This model has no PoE ports. PoE ports are available only on the 4P-2GT-2GS models of the EDS-4008 Series. For a PoE application, choose one of those models instead.
Does the EDS-4008-2SSC-LV support time synchronization for power substations?
Yes. The switch supports hardware-based IEEE 1588v2 PTP. It lists three power profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, and IEEE C37.238-2017. This lets substation devices that follow these profiles keep their clocks aligned across the network.
Send an inquiry with the Enquire Now button, or contact Rockford to ask about the MOXA EDS-4008-2SSC-LV Managed Ethernet Switch in Qatar. Rockford offers pre-sales support, network design, consulting, technical support, and training to help match the switch to your network.